Modules mduta modular

Central module

Technical data
Power supply
mduta modular 24 VDC (±10%), Typ. 3 A
Sensor supply voltage (only measurement side) 24 VDC (±10%), Typ. 5 A
Load supply voltage (only power side) 24 VDC (±5%), Typ. 40 A
General
IP – Code IP 54 (only in the installed state)
Working temperature range -40 °C bis 85 °C
Dimensions (L x W x H) 200 x 80 x 116 mm
Weight ca.1220 g

 

Modules of the measurement side (left side)

digital IN/OUT 24 V
8 x digital I/O – Module
  • configurable as input or output
Counter Module
4 x Counter
  • configurable as 1- or 2- channel counter
  • or encoder input
analog IN DMS
4 x strain gauge
  • for use with load cells with 4-wire-connection
analog IN Thermo
4 x Thermocouple
  • for use with thermocouples type  J, T, E, N, S, R and K
analog IN ±25 V
4 x voltage measurement
  • voltage reference 10V
key SIM
6 x key – simulation channels
  • simulates resistance-coded push-buttons

 

Modules of the power side (right side)

Power
1 x adjustable power supply
  • output voltage 5 V … 18 V / 40 A
  • potential-free relay (14 V / 2 A)
  • series resistor simulation (0 … 250 mΩ)
Relay Basic
  • connection of the external supply voltage
Relay Extension
  • configurable as make contact, break contact, distributor, quarterbridge, halfbridge

 

Do you wish more information?